Mojette transform
This article has multiple issues. Please help improve it or discuss these issues on the talk page. (Learn how and when to remove these messages)
|
The Mojette transform is an application of discrete geometry. More specifically, it is a discrete and exact version of the Radon transform, thus a projection operator.
The IRCCyN laboratory - UMR CNRS 6597 in Nantes, France has been developing it since 1994.
The first characteristic of the Mojette transform is using only additions and subtractions. The second characteristic is that the Mojette Transform is redundant, spreading the initial geometrical information into several projections.
This transform uses discrete geometry in order to dispatch information onto a discrete geometrical support. This support is then projected by the Mojette operator along discrete directions. When enough projections are available, the initial information can be reconstructed.
The Mojette transform has been already used in numerous applications domains:
- Medical tomography
- Network packet transfer
- Distributed storage on disks or networks
- Image fingerprinting and image cryptography schemes
History
[edit]After one year of research, the first communication introducing the Mojette Transform was held in May 1995 in the first edition of CORESA National Congress CCITT Rennes. Many others will follow it for 18 years of existence. In 2011, the book The Mojette Transform: Theory and Applications at ISTE-Wiley was well received by the scientific community. All this support has encouraged the IRCCyN research team to continue the research on this topic.
Jeanpierre Guédon, professor and inventor of the transform called it: "Mojette Transform". The word "Mojette" comes from the name of white beans in Vendee, originally written "Moghette" or "Mojhette". In many countries, bean is a basic educational tool representing an exact unit that teaches visually additions and subtractions. Therefore, the choice of the name "Mojette" serves to emphasize the fact that the transform uses only exact unit in additions and subtractions.
The original purpose of the Mojette Transform was to create a discrete tool to divide the Fourier plane into angular and radial sectors. The first attempt of application was the psychovisual encoding of image, reproducing the human vision channel. However, it was never realized.
Mathematics
[edit]The "raw" transform Mojette definition is this:
The following figure 1 helps to explain the ârawâ transform Mojette.

We start with the function f represented by 16 pixels from p1 to p16. The possible values of the function at the point (k, l) are different according to the applications. This can be a binary value of 0 or 1 that it often used to differentiate the object and the background. This can be a ternary value as in the Mojette game. This can be also a finite set of integers value from 0 to (n-1), or more often we take a set of cardinality equal to a power of 2 or a prime number. But it can be integers and real numbers with an infinite number of possibilities, even though this idea has never been used.
With the index "k" as "kolumn" and âlâ as a âlineâ, we define a Cartesian coordinate system. But here we will only need the integer coordinates. On Figure 2, we have arbitrarily chosen the left bottom point as the origin (0,0) and the direction of the two axes. The coordinates of each pixel are denoted in red on Figure 2.
For the projections, the coordinate system is derived from that of the grid. Indeed, it meets two requirements: 1) The pixel (0,0) is always projected on the point 0 of the projection (this is a consequence of linearity of the Mojette operator) 2) The direction of the projection is fixed "counterclockwise" as in trigonometry when going from 0 ° to 180 °.
Altogether, it necessarily gives the positions of the bins like the ones in blue color on the Figure 2. Letâs head back to the formula (1): the red dots correspond to the index (k, l) and the blue dots to the index b. The only elements remaining to clarify are the (p, q) values.
These two values (p, q) are precisely those characterizing the Mojette Transform. They define the projection angle. Figure 3 shows colored arrows corresponding with the color code to the projection indexed by (p, q). For the 90° angle, the projection is shown below the grid for convenience but the direction is upward. Table 1 shows the correspondence between the angles in degrees and the values of p and q.
| 0° | p=1 | q=0 | b-l=0 |
| 45° | p=1 | q=1 | b+k-l=0 |
| 90° | p=0 | q=1 | b+k=0 |
| 135° | p=-1 | q=1 | b+k+l=0 |
The only valid Mojette angles are given by the following rules:
- An angle is given by the direction of projection in line and column
- A direction is composed of two integers (p, q) with gcd (p, q) = 1
- An angle is always between 0 and 180 °, which means that q is never negative
These rules ensure the uniqueness in the correspondence of an angle and (p, q) values. For example, the 45 ° angle, the Rule 2 forbid to define the angle pairs (2,2) or (3,3) and Rule 3 prohibits to use (-2, -2) and (-1, -1). Only the angle (p = 1, q = 1) satisfies the three rules.
Applications and achievements
[edit]The distributed storage disk or network
[edit]The most important area of application using the "Mojette Transform" is distributed storage. Particularly, this method is used in RozoFS, an open-source distributed file system. In this application, the "Mojette Transform" is used as an erasure code in order to provide reliability, while significantly reducing the total amount of stored data when compared to classical techniques like replication (typically by a factor of 2). Thus, it significantly reduces the cost of the storage cluster in terms of hardware, maintenance or energy consumption for example.
In 2010, Pierre Evenou, research engineer of the IVC team IRCCyN laboratory, decided to create the start-up Fizians (currently known as Rozo Systems) using this application. The start-up offers storage solutions in cloud computing, virtualization, storage servers, file servers, backup and archiving.
Networks packets transfer
[edit]Thanks to the redundancy of the transform, sent packets can be fragmented without loss. Additionally, the fact of using only additions and subtractions increases the speed of information transmission. Finally, the information cannot be reconstructed without having the initial angle of the projections, so it also provides data security.
This application has been selected by Thales Cholet for its ad hoc network (using wireless network and terminals to transmit messages between them) in order to secure the information and has multiple paths between the source and destination. In 2002, the start-up PIBI has used this technology to provide secure Internet payment services.
The Medical tomography
[edit]In the field of medical imaging, the properties of the âTransform Mojetteâ create a direct mapping and solve the missing wedge problem. However, the image acquisition using the Mojette transform has not been yet developed. The problem of obtaining exact âMojetteâ values while using approximated data acquisition has been studied but has to be continued. Besides, the post-processing of medical images is doing well since data acquisition is already done.
These results are used by the company Keosys in 2001 with Jerome Fortineau and the company Qualiformed created in 2006 by Stephen Beaumont. Prof. Guédon and the IRCCyN laboratory were heavily involved in the creation of these two companies. The companies have already financed several PhD students and participated in research projects in order to continue the development of the application in medical tomography. The results have led to apply patents and implementation on their equipment of image processing.
The watermarking and image encryption
[edit]Cryptography and watermarking were also part of the research conducted in the IRCCyN laboratory. It provides solutions for security and authentication.
In cryptography, the instability of the transformed Mojette secures data. The fact that the transform is exact encrypts information and allows no deviation even minimal. For watermarking, the transform is very effective in fingerprinting. By inserting "Mojette Transform" marks in images, one can authenticate documents using the same properties as in cryptography.
Bibliography
[edit]- Jeanpierre GuĂ©don, N. Normand, B. Parrein, and C. Pouliquen, âDistributed image transmission and storage on Internet system,â in ACIDCA, 2000, pp. 164â169.
- B. Parrein, N. Normand, and J. GuĂ©don, âMultiple description coding using exact discrete Radon transform,â in IEEE Data Compression Conference, 2001, p. 508.
- J. GuĂ©don, N. Normand, P. Verbert, B. Parrein, F. Autrusseau, âLoad-balancing and scalable multimedia distribution using the Mojette transform,â in Internet Multimedia Management Systems II, ITCOM, 2001, pp. 226â234.
- J. GuĂ©don, B. Parrein, N. Normand, âInternet Distributed Image Information System,â Integrated Computer-Aided Engineering, vol. 8, no. 3, pp. 205â214, Sep. 2008.
- B. Parrein, âDescription multiple de lâinformation par transformation Mojette,â UniversitĂ© de Nantes, 2008.
- F. Autrusseau and J. GuĂ©don, âImage watermarking for copyright protection and data hiding via the Mojette transform,â in Security and Watermarking of Multimedia Contents IV, 2002, pp. 378â386.
- F. Autrusseau and J. GuĂ©don, âImage Watermarking in the Fourier Domain Using the Mojette Transform,â in Digital Signal Processing, 2002, pp. 725â728.
- F. Autrusseau, âModĂ©lisation Psychovisuelle pour le tatouage des images,â UniversitĂ© de Nantes, 2011.
- F. Autrusseau and J. GuĂ©don, âA joint multiple description-encryption image algorithm,â in International Conference on Image Processing, 2003, pp. 269â272.
- J. GuĂ©don, N. Normand, and B. Parrein, âMultimedia packet transport: multiple layers or descriptions?,â in IEEE Packet Video workshop, 2003, p. 7 p.
- B. Parrein, N. Normand, and J. GuĂ©don, âMultimedia forward error correcting codes for wireless LAN,â Annales des TĂ©lĂ©communications, vol. 58, no. 3â4, pp. 448â463, Jul. 2008.
- F. Autrusseau and J. GuĂ©don, âChiffrement Mojette dâimages mĂ©dicales,â IngĂ©nierie des SystĂšmes dâInformation (ISI), vol. 8, no. 1, pp. 113â134, Feb. 2008.
- O. DĂ©forges, M. Babel, N. Normand, B. Parrein, J. Ronsin, J. GuĂ©don, and L. BĂ©dat, âLe LAR aux Mojettes,â in CORESA 04 - COmpression et REprĂ©sentation des Signaux Audiovisuels, 2004, pp. 165â168.
- P. Verbert, V. Ricordel, J. GuĂ©don, and P. Verbert, âAnalysis of mojette transform projections for an efficient coding,â in Workshop on Image Analysis for Multimedia Interactive Services (WIAMIS, 2004, p. -.
- M. Babel, B. Parrein, O. DĂ©forges, N. Normand, J. GuĂ©don, and J. Ronsin, âSecured and progressive transmission of compressed images on the Internet: application to telemedicine,â in SPIE 17th Annual Symposium / Electronic Imaging - Internet Imaging, 2005, pp. 126â136.
- J. GuĂ©don and N. Normand, âThe Mojette Transform: The First Ten Years,â in Discrete Geometry for Computer Imagery, 2005, vol. 3429, pp. 79â91.
- M. ServiĂšres, N. Normand, J. GuĂ©don, and Y. Bizais, âThe Mojette Transform: Discrete Angles for Tomography,â in Discrete Tomography and its Applications, 2005, vol. 20, pp. 587â606.
- M. Servieres, âReconstruction Tomographique Mojette,â UniversitĂ© de Nantes; Ecole centrale de nantes - ECN, 2009.
- F. Autrusseau, P. Evenou, and T. Hamon, âSecure Distributed Storage based on the Mojette transform,â in Nouvelles technologies de la rĂ©partition, 2006, pp. 161â170.
- F. Autrusseau, B. Parrein, and M. Servieres, âLossless Compression Based on a Discrete and Exact Radon Transform: A Preliminary Study,â in International Conference on Acoustics, Speech and Signal Processing, 2006, pp. 425â428.
- M. Kalantari, F. Jung, G. Moreau, and J. GuĂ©don, âDĂ©tection entiĂšrement automatique de points de fuite dans des scĂšnes architecturales urbaines,â in CORESA 2006 COmpression et REprĂ©sentation des Signaux Audiovisuels, 2006, pp. 41â46.
- E. Denis, J. GuĂ©don, S. Beaumont, and N. Normand, âDiscrete and continuous description of a three dimensional scene for quality control of radiotherapy treatment planning systems,â in Medical Imaging, 2006, vol. 6142, p. 187.
- M. ServiĂšres, N. Normand, and J. GuĂ©don, âInterpolation method for the Mojette Transform,â in Medical Imaging 2006: Physics of Medical Imaging, 2006, vol. 6142, p. 61424I.
- N. Normand, A. Kingston, and P. Ăvenou, âA Geometry Driven Reconstruction Algorithm for the Mojette Transform,â in Discrete Geometry for Computer Imagery, 2006, vol. 4245, pp. 122â133.
- S. Hamma, E. Cizeron, H. Issaka, and J. GuĂ©don, âPerformance evaluation of reactive and proactive routing protocol in IEEE 802.11 ad hoc network,â in ITCom 06 - next generation and sensor networks, 2008, p. 638709.
- M. Kalantari and M. Kasser, âImplementation of a low-cost photogrammetric methodology for 3d modelling of ceramic fragments,â in XXI International CIPA Symposium, 01-6 October, Athens, Greece, 2007, p. FP079.
- A. Kingston, S. Colosimo, P. Campisi, and F. Autrusseau, âLossless Image Compression and Selective Encryption Using a Discrete Radon Transform,â in International Conference on Image Processing, 2007, pp. 465â468.
- E. Denis, S. Beaumont, J. GuĂ©don, N. Normand, and T. Torfeh, âAutomatic quality control of digitally reconstructed radiograph computation and comparison with standard methods,â in Medical Imaging 2007: Physics of Medical Imaging, 2007, vol. 6510, p. 65104J.
- A. Daurat and N. Normand, âTransformation et reconstruction par projections,â in GĂ©omĂ©trie discrĂšte et images numĂ©riques, A. M. David Coeurjolly, Ed. HermĂšs, 2008, pp. 239â251.
- N. Normand and J. GuĂ©don, âApplications de la transformation Mojette,â in GĂ©omĂ©trie discrĂšte et images numĂ©riques, A. M. David Coeurjolly, Ed. HermĂšs, 2008, pp. 337â347.
- B. Parrein, F. Boulos, P. Le Callet, and J. GuĂ©don, âPriority image and video encoding transmission based on a discrete Radon transform,â in IEEE Packet Video 2007, 2007, p. 6 pages.
- S. Chandra, I. Svalbe, and J. GuĂ©don, âAn exact, non-iterative Mojette inversion technique utilising ghosts,â in 14th IAPR international conference on Discrete geometry for computer imagery, 2008, p. .
- H. Fayad, J. GuĂ©don, I. Svalbe, N. Normand, and Y. Bizais, âMojette and FRT tomographs,â in Medical Imaging 2008, 2008, vol. 6913, p. -.
- M. Kalantari, F. Jung, J. GuĂ©don, and N. Paparoditis, âDĂ©tection automatique des points de fuite et calcul de leur incertitude Ă lâaide de la gĂ©omĂ©trie projective,â in RFIA 2008, 2008, pp. 703â712.
- M. Kalantari, F. Jung, N. Paparoditis, and J. GuĂ©don, âRobust and automatic vanishing points detection with their uncertainties from a single uncalibrated image, by planes extraction on the unit SPHERE,â in ISPRS2008, 2008, pp. 203â208.
- H. Fayad, J. GuĂ©don, I. Svalbe, Y. Bizais, and N. Normand, âApplying Mojette discrete Radon transforms to classical tomographic data,â in Medical Imaging, 2008, vol. 6913, p. 69132S.
- A. Kingston and F. Autrusseau, âLossless Image Compression via Predictive Coding of Discrete Radon Projections,â Signal Processing Image Communication, vol. 23, no. 4, pp. 313â324, Jun. 2008.
- E. Denis, S. Beaumont, J. GuĂ©don, T. Torfeh, N. Normand, and A. Norbert, âNew automatic quality control methods for geometrical treatment planning system tools in external conformal radiotherapy,â in Medical Imaging 2008: Physics of Medical Imaging, 2008, vol. 6913, p. 69133F.
- M. Babel, B. Parrein, O. DĂ©forges, N. Normand, J. GuĂ©don, and V. Coat, âJoint source-channel coding: secured and progressive transmission of compressed medical images on the Internet,â Computerized Medical Imaging and Graphics, vol. 32, no. 4, pp. 258â269, Apr. 2008.
- E. Denis, S. Beaumont, J. GuĂ©don, T. Torfeh, N. Normand, and N. Ailleres, âNouvelle mĂ©thode automatique de contrĂŽle de qualitĂ© des systĂšmes de planification gĂ©omĂ©trique des traitements en radiothĂ©rapie externe conformationnelle,â in JournĂ©es scientifiques de la SociĂ©tĂ© Française de Physique MĂ©dicale, 2008, p. denis.
- A. Kingston, B. Parrein, and F. Autrusseau, âRedundant Image Representation via Multi-Scale Digital Radon Projection,â in International Conf. of Image Processing, 2008, p. 2069.
- P. Jia, J. Dong, L. Qi, and F. Autrusseau, âDirectionality Measurement and Illumination Estimation of 3D Surface Textures by Using Mojette Transform,â in 19th International Conference on Pattern Recognition, 2010, p. 1144.
- Y. Ben Hdech, J. GuĂ©don, and S. Beaumont, âSimulations Monte Carlo dâun faisceau de RX issus dâun accĂ©lĂ©rateur VARIAN : influence du paramĂ©trage des Ă©lectrons initiaux,â in JournĂ©es Scientifiques de la SociĂ©tĂ© Française de Physique MĂ©dicale (SFPM) 2009 : Innovations et bĂ©nĂ©fices thĂ©rapeutiques : quelles limites?, 2009, p. 1.
- Y. Ben Hdech, J. GuĂ©don, and S. Beaumont, âDes Objets-Tests NumĂ©riques (OTN) anatomiques pour le ContrĂŽle QualitĂ© (CQ) de SystĂšmes de Planification de Traitement (TPS) en radiothĂ©rapie,â in JournĂ©es Scientifiques de la SociĂ©tĂ© Française de Physique MĂ©dicale (SFPM) 2009 : Innovations et bĂ©nĂ©fices thĂ©rapeutiques : quelles limites?, 2009, p. 1.
- M. Kalantari, F. Jung, J. GuĂ©don, and N. Paparoditis, âThe Five Points Pose Problem : A New and Accurate Solution Adapted to any Geometric Configuration,â in The Pacific-Rim Symposium on Image and Video Technology (PSIVT), 2009, vol. 5414, p. .
- D. Coeurjolly and N. Normand, âDiscrete geometry and projections (chap 1),â in The Mojette Transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 15 pages.
- J. GuĂ©don and N. Normand, âReconstructability with the inverse Mojette transform (chap 4),â in The Mojette Transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 15 pages.
- J. GuĂ©don and N. Normand, âDirect Mojette transform (chap 3),â in The Mojette Transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 23 pages.
- A. Kingston and F. Autrusseau, âLossless compression (chap 9),â in The Mojette transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 19 pages.
- A. Kingston, F. Autrusseau, E. Grall, T. Hamon, and B. Parrein, âMojette based security (chap 10),â in The Mojette transform: Theory and Applications, J. GuĂ©don, Ed. iste & wiley, 2009, p. 25 pages.
- A. Kingston, F. Autrusseau, and B. Parrein, âMultiresolution Mojette transform (chap 6),â in The Mojette transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 29 pages.
- N. Normand, I. Svalbe, P. Evenou, and A. Kingston, âInverse Mojette transform algorithms (chap 5),â in The Mojette Transform: Theory and Applications, J. GuĂ©don, Ed. iste & wiley, 2009, p. 25 pages.
- B. Parrein, F. Boulos, N. Normand, and P. Evenou, âCommunication, networks and storage (chap 7),â in The Mojette Transform: Theory and Applications, J. GuĂ©don, Ed. iste & wiley, 2009, p. 29 pages.
- M. ServiĂšres, J. GuĂ©don, N. Normand, and Y. Bizais, âMojette discrete tomography (chap 8),â in The Mojette Transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 29 pages.
- I. Svalbe and J. GuĂ©don, âDiscrete versions of the Radon Transform (chap 2),â in The Mojette Transform: Theory and Applications, jeanpierre GuĂ©don, Ed. iste & wiley, 2009, p. 17 pages.
- J. Guédon, The Mojette transform. Theory and applications. ISTE-WILEY, 2009.
- S. Beaumont, J. GuĂ©don, and Y. Ben Hdech, âContrĂŽle qualitĂ© dosimĂ©trique des systĂšmes de planification de traitement : nouvelle mĂ©thode basĂ©e sur lâutilisation de PENELOPE et des Objets Tests NumĂ©riques anatomiques,â in JournĂ©es Scientifiques de la SociĂ©tĂ© Française de Physique MĂ©dicale (SFPM), 2010, p. 1.
- Y. Ben Hdech, S. Beaumont, and J. GuĂ©don, âDĂ©veloppement dâune mĂ©thode de ContrĂŽle qualitĂ© des SystĂšmes de Planification des Traitements, utilisĂ©s en radiothĂ©rapie, au moyen du code Monte-Carlo PENELOPE et des Objets Tests NumĂ©riques,â in JournĂ©e des doctorants de lâĂcole Doctorale STIM JDOC, 2010, p. 1.
- Y. Ben Hdech, S. Beaumont, J. GuĂ©don, and T. Torfeh, âNew method to perform dosimetric quality control of treatment planning system using PENELOPE Monte-Carlo and anatomical digital test objects,â in SPIE Medical Imaging 2010, 2010, vol. 7622, p. .
- Y. Amouriq, P. Evenou, A. Arlicot, N. Normand, and P. Layrolle, âEvaluation of trabecular bone patterns on dental radiographic images: influence of cortical bone,â in SPIE Medical Imaging, 2010, vol. 7626, p. 76261M.
- Y. Amouriq, P. Evenou, A. Arlicot, N. Normand, P. Layrolle, P. Weiss, and J. GuĂ©don, âEvaluation of trabecular bone patterns on dental radiographic images: influence of cortical bone,â in SPIE Medical Imaging, 2010, p. 10 pages.
- A. Arlicot, Y. Amouriq, P. Evenou, N. Normand, and J. GuĂ©don, âA single scan skeletonization algorithm: application to medical imaging of trabecular bone,â in SPIE Medical Imaging, 2010, vol. 7623, p. 762317.
- C. Zhang, J. Dong, J. Li, and F. Autrusseau, âA New Information Hiding Method for Image Watermarking Based on Mojette Transform,â in Second International Symposium on Networking and Network Security, 2010, pp. 124â128.
- N. Normand, I. Svalbe, B. Parrein, and A. Kingston, âErasure Coding with the Finite Radon Transform,â in Wireless Communications & Networking Conference, 2010, pp. 1â6.
- S. S. Chandra, N. Normand, A. Kingston, J. GuĂ©don, and I. Svalbe, âFast Mojette Transform for Discrete Tomography,â 13-Jul-2012.
- J. GuĂ©don, C. Liu, and J. GuĂ©don, âThe 2 and 3 materials scene reconstructed from some line Mojette projections,â in IEEE IPTA Conference, 2010, p. 6.
- Y. Amouriq, J. GuĂ©don, N. Normand, A. Arlicot, Y. Ben Hdech, and P. Weiss, âBone texture analysis on dental radiographic images: results with several angulated radiographs on the same region of interest,â in SPIE Medical Imaging 2011: Biomedical Applications in Molecular, Structural, and Functional Imaging, 2012, vol. 7965, p. 796525.
- S. Beaumont, T. Torfeh, R. Latreille, Y. Ben Hdech, and J. GuĂ©don, âNew method to test the gantry, collimator and table rotation angles of a linear accelerator used in radiation therapy,â in SPIE Medical Imaging 2011, 2011, vol. 7961, p. 796153.
- Y. Ben Hdech, S. Beaumont, J. GuĂ©don, and C. Sylvain, âDosimetric quality control of Eclipse treatment planning system using pelvic digital test object,â in Medical Imaging 2011: Physics of Medical Imaging, 2011, vol. 7961, p. 79613F.
- A. Arlicot, P. Evenou, and N. Normand, âSingle-scan skeletonization driven by a neighborhood-sequence distance,â in International workshop on Combinatorial Image Analysis, IWCIA, 2011, pp. 61â72.
- A. Arlicot, N. Normand, Y. Amouriq, and J. GuĂ©don, âExtraction of bone structure with a single-scan skeletonization driven by distance,â in First Sino-French Workshop on Education and Research collaborations in Information and Communication Technologies, SIFWICT, 2011, p. 2 pages.
- Y. Ben Hdech, D. Autret, S. Beaumont, and J. GuĂ©don, âTPS dosimetric evaluation using 1540-IAEA Package and Monte-Carlo simulations,â in ESTRO International Oncology Forum, 2011, p. 1.
- C. Liu, J. GuĂ©don, I. Svalbe, and Y. Amouriq, âLine Mojette ternary reconstructions and ghosts,â in IWCIA, 2011, p. 11.
- C. Liu and J. GuĂ©don, âThe limited material scenes reconstructed by line Mojette algorithms,â in Franco-Chinese conference, 2011, p. 2.
- J. Dong, L. Su, Y. Zhang, F. Autrusseau, and Y. Zhanbin, âEstimating Illumination Direction of 3D Surface Texture Based on Active Basis and Mojette Transform,â Journal of Electronic Imaging, vol. 21, no. 013023, p. 28 pages, Apr. 2012.
- D. Pertin, G. DâIppolito, N. Normand, and B. Parrein, âSpatial Implementation for Erasure Coding by Finite Radon Transform,â in International Symposium on signal, Image, Video and Communication 2012, 2012, pp. 1â4.
- P. BlĂ©ry, Y. Amouriq, J. GuĂ©don, P. Pilet, N. Normand, N. Durand, F. Espitalier, A. Arlicot, O. Malard, and P. Weiss, âMicroarchitecture of irradiated bone: comparison with healthy bone,â in SPIE Medical Imaging, 2012, vol. 8317, p. 831719.
- S. Chandra, I. Svalbe, J. Guedon, A. Kingston, and N. Normand, âRecovering Missing Slices of the Discrete Fourier Transform using Ghosts,â IEEE Transactions on Image Processing, vol. 21, no. 10, pp. 4431â4441, Jul. 2012.
- H. Der Sarkissian, Jp. Guédon, P. Tervé, N. Normand and I. Svalbe. (2012)." Evaluation of Discrete Angles Rotation Degradation for Myocardial Perfusion Imaging", EANM Annual Congress 2012.
- C. Liu and J. GuĂ©don, âFinding all solutions of the 3 materials problem,â in proceedings of SIFWICT, 2013, p. 6.
- B. Recur, H. Der Sarkissian, Jp. GuĂ©don and I.Svalbe, "TomosynthĂšse Ă lâaide de transformĂ©es discrĂštes", in Proceeding TAIMA 2013
- H. Der Sarkissian, B. Recur, N. Normand and Jp. Guédon, "Mojette space Transformations", in proceedings of SWIFCT 2013.
- B. Recur, H. Der Sarkissian, M. ServiÚres, N.Normand, Jp. Guédon, "Validation of Mojette Reconstruction from Radon Acquisitions" in Proceedings of 2013 IEEE International Conference on Image Processing.
- H. Der Sarkissian, B. Recur, N. Normand, Jp. Guédon. (2013), "Rotations in the Mojette Space" in 2013 IEEE International Conference on Image Processing.
External links
[edit]
Media related to Mojette Transform at Wikimedia Commons